operation

Attach handles

The fallaway handles are used to open and close the

front doors. Remove after each use so they will not get

hot. Keep in convenient location for each use. (Fig. 27)
Assemble the primary air control and damper handles

by passing the 3³⁄₈” screw through the ceramic shaft

and into the bright metal hub. Tighten carefully until

snug. Do not overtighten. Ceramic handle could crack.
(Fig. 28)

5167

EPA36

cover

3/02

FP1397

Fig. 27 Insert fallaway handles into door handle stubs.

Steel Handle

Fallaway Handle

EWF36A controls

Three controls regulate the performance of the EW-

F36A fireplace: A primary air control supplies oxy-

gen for the fire, the damper directs air flow within the

fireplace and a variable-speed fan control, or rheostat,

regulates the warm air flow into the room. (Fig. 29)

primary Air control

A single air control regulates the amount of heat the fire

will produce and how long it will burn.

FP1396
EWF handles
8/14/03 djt

FP1396

Fig. 28 Assemble primary air control and damper handles.

Screw

Ceramic Shaft

Metal Hub

The

primary air control is located in the upper left

corner of the unit. (Fig. 27) It is the primary source of

air for starting, maintaining, and reviving the fire.
Generally, more air entering the fireplace makes the fire

burn hotter and faster, while less air prolongs the burn.
The air supply is open to the maximum when the control

lever is rotated clockwise, and closed when rotated

counterclockwise. To vary the burn rate, adjust the con-

trol to the desired position in between these extremes;

opening the primary air control makes the unit burn

hotter. Closing the control slows the unit down. You may

adjust to any position you desire.

The Damper

The damper directs air flow within the fireplace.
The

damper is operated by moving the lever located

in the upper right corner of the unit. It has two posi-

tions: Open to start or revive the fire and closed, for

normal operation and to control burn rate. The damper

is open when the lever is fully rotated counterclockwise

and pulled out and closed when pushed in. When the

damper is in the open position, with the lever pulled out,

and rotated fully in the clockwise direction, the handle

can ‘telescope’ back without closing the damper or any

damper movement. There are no intermediate settings

for the damper.
NoTE: Full clockwise or counterclockwise movement of

the damper handle is approximately 50°.
NoTE: Always open the damper before opening the

doors. Close damper to set burn rate.

FP1204

EPA36

controls

3/20/02 djt

Primary Air Control

FP1203

Fig. 29 EWF36A controls.

Damper