Installation, Chase installation – MHP EWF36A User Manual

Page 8

Advertising
background image

8

Vermont Castings EWF36A

20005167

chimney Supports

The chimney system is supported by the fireplace for

vertical chimney heights less than 30’ (9m) above the

hearth. Chimney supports are required if the vertical

height exceeds 30’ (9m). Locate chimney supports

at ceiling holes or other structural framing at 30’ (9m)

heights. Spacing between chimney supports

must not

exceed 30’ (9m). Use Chimney Support Model TCS8A.

(NoTE: The TcS8A cannot be mounted directly to

the fireplace.) Support provided by elbow straps fulfills

the support requirement only if they are spaced as pre-

viously described. (A chimney support is 2¹⁄₂" (64mm)

long when installed.)
Angled chimney runs require a support every 6’ (1.8m)

in addition to the elbow straps. Chimney supports are
used for this function. (Fig. 6)

FP284a

TCS8A

8/21/00

Chimney Sup-

port Strap

TCS8A

FP284a

Fig. 6 Chimney support installation.

chase installation

A chase is a vertical box-like structure which encloses

the fireplace and/or chimney. Chases are typically built

on the outside of the house with fireplace opening cut

into the outer wall of a room. (Page 5, Fig. 2)
If you need help in determining fireplace location or how

the chimney system should be run, contact your Ver-

mont Castings dealer for assistance.

insulating Fireplace Enclosure

for cold climates

If you live in a cold climate, it is not required but

highly recommended that you insulate fireplace

enclosure to eliminate cold air penetration as much as

possible.
Insulate base of fireplace with a noncombustible

insulation rated for a minimum of 300° F. Insulating

is

very important for outside wall installations over

a concrete slab. If fireplace is installed on a platform,

insulation should be placed on top of the platform

before fireplace is set. (Fig. 7)
When a fireplace is installed in a chase or on an

outside wall, enclosure should be treated like any

outside wall in a home. Insulation should be installed

on the inside wall as well as the outside wall(s). In a

chase, it is also a good idea to install a firestop at the

first ceiling level above the fireplace and enclose the

chase with sheeting material. Insulation may then be

installed above sheeting material to assure the space

around the fireplace is totally protected. (Fig. 2)
When installing the chimney,

Do NoT caulk between

outer pipe and firestop. It is vital that some air be al-

lowed to flow through this very thin gap.
cAUTioN: When installing a fireplace in an insu-

lated enclosure, be sure all required air spaces

are maintained. (page 13, Fig. 17)

installation

FPC555a

Platform insulation

BFC model

8/21/00 djt

Hard

Flat

Surface

Insulation

Platform

FPC555a

Fig. 7 Insulating between platform and fireplace.