Country code, displaying, Diagnostic information, displaying, Fallback – Multi-Tech Systems MT5634MSV User Manual

Page 41: Handshake, Modulation handshake command, Monitor speaker mode command, Monitor speaker volume command, Pulse dialing command, Return online to data mode command, Speaker mode command

Advertising
background image

4 AT Commands, S-Registers, and Result Codes

33

I5

Display the board ID: software version, hardware version, and
country ID

I9

Display the country code (e.g., NA Ver. 1).

I11

Display diagnostic information for the last modem connection,
such as DSP and firmware version, link type, line speed, serial
speed, type of error correction/data compression, number of
past retrains, etc.

Command:

L

n

Monitor Speaker Volume

Values:

n = 0, 1, 2, or 3

Default:

2

Description:

L0

Select low volume.

L1

Select low volume.

L2

Select medium volume.

L3

Select high volume.

Command:

M

n

Monitor Speaker Mode

Values:

n = 0, 1, 2, or 3

Default:

1

Description:

M0

Speaker always off.

M1

Speaker on until carrier signal detected.

M2

Speaker always on when modem is off-hook.

M3

Speaker on until carrier is detected, except while dialing.

Command:

N

n

Modulation Handshake

Values:

n = 0 or 1

Default:

1

Description:

N0

Modem performs handshake only at communication standard
specified by S37 and the B command.

N1

Modem begins handshake at communication standard speci-
fied by S37 and the B command. During handshake, fallback to
a lower speed can occur.

Command:

O

n

Return Online to Data Mode

Values:

0, 1, 3

Default:

None

Description:

O0

Exit online command mode and return to data mode (see
+++AT<CR>

escape sequence ).

O1

Issue a retrain and return to online data mode.

O3

Issue a rate renegotiation and return to data mode.

Command:

P

Pulse Dialing

Values:

P, T

Default:

T

Description:

Configures the modem for pulse (non-touch-tone) dialing.
Dialed digits are pulsed until a T command or dial modifier is
received.

Advertising