Motorola PTP 400 Series User Manual

Page 141

Advertising
background image

139

Power Indoor Unit LED check chart:

Mode

Green
LED

Yellow LED No
Ethernet Cable
Connected

Yellow LED Ethernet Cable
Connected between PIDU Plus and
NIC/Switch/Hub

No Power Applied

Off

Off

Off

Power Applied

On

Will flash once per
second regularly
approximately 16
seconds after power
applied for 10
seconds then will go
out and stay out

Will flash regularly once per second
approximately 16 seconds after
power applied for 10 seconds then
operate as Ethernet Link/Activity
LED

Valid Ethernet Link and
no traffic

On

N/A

Will be on solid for a valid link.

Valid Ethernet Link with
traffic

On N/A

Will be on solid, but will blink
randomly as traffic passes through

While Recovery Switch
Pressed

On Off

Off

Recovery Switch Pressed
and released within 10
seconds during normal
operation

On Off

Off while switch pressed but returns
to LINK/Activity state when
released. No reset will take place

Recovery Switch Pressed
and held for > 20
seconds during normal
operation

On

Off while switch pressed.
One second after release, flashes twice per second
regularly for 10 seconds, then erases non-volatile
configuration data and resets. The erasure will reset all the
unit's configuration apart from the last known wireless link
configuration. This ensures that after a reset the wireless
link SHOULD re-establish without any user intervention.
The IP address will be reset to 169.254.1.1

27

Recovery Switch Pressed
and held for >40 seconds
from power on (Recovery
is pressed while power is
applied)

On

Off while switch pressed.
One second after release, flashes regularly twice per
second for 10 seconds. Then erases non-volatile
configuration data & the downloaded image and resets.
The erasure will reset all the unit's configuration apart from
the last known wireless link configuration. This ensures that
after a reset the wireless link SHOULD re-establish without
any user intervention.
The IP address will be reset to 169.254.1.1 and the unit will
boot the fixed software image.

27

It is possible that some units may have been previously configured with IP addresses 10.10.10.10

(Slave) and 10.10.10.11 (Master). Therefore the IP address will be reset to 10.10.10.10/11.

Advertising