The length of the safety lanyard must not exceed 1m (approx 3 ft) in length. The lanyard

should be made from a material that does not degrade in an outdoor environment.

The safety lanyard must be fixed to a separate fixing point that is not part of the direct

mounting system for the ODU.

7.7 Connecting

Up

7.7.1 Preparing The Cable — RJ45 connections

Cables should be prepared using the following instructions along with the cable and

connector supplier’s instructions:

Step 1: Assemble gland Step on cable as

shown

Step 2: Strip the outer insulation

Step 3: Arrange conductors as shown in

Figure 19 and cut to length

Step 4: Insert conductors and crimp