6 surge arrestor, 7 mounting brackets, Surge arrestor – Motorola PTP 400 Series User Manual

Page 35: Mounting brackets

Advertising
background image

33

The connection between the PTP 400 Series Bridge PIDU Plus and the user’s equipment can

be made using any standard CAT5 patch cable. The RJ45 Ethernet connection is presented

as a piece of network equipment. However as automatic MDI/MDI-X sensing and pair

swapping is employed a crossed Ethernet patch cable can be used for connection to another

piece of networking equipment or directly to end user equipment.

It should be noted that the PIDU Plus provides continuity between the screen on the ODU to

PIDU Plus cable and screen on the PIDU Plus-User equipment cable. If continuity of the

screening is desired from the ODU to the PIDU Plus to the user’s equipment, CAT5 STP

cable and connectors should be used for the latter connection. CAT5 STP cable between the

PIDU Plus and the user’s equipment will provide additional protection against surges induced

on the Ethernet connections.

3.3.6 Surge Arrestor

The PTP 400 Series Bridge PIDU Plus does not provide lightning or surge suppression.

Should lightning or surge suppression be required a separate Ethernet surge suppressor

should be used and appropriately earthed. Suitable surge suppressors can be sourced from

your Motorola Point-to-Point Distributor or Solutions Provider. The ODU is protected by built-

in surge suppression as standard. See 11 “Lightning Protection”.

3.3.7 Mounting

Brackets

The PTP 400 Series Bridge is supplied with a mounting bracket suitable for mounting the

ODU to a pole of 25mm (1”) to 75mm (3”) in diameter. For more details on mounting, see

section 7 “Installation”.

The bracket allows for adjustment in both azimuth and elevation.

The PIDU Plus can either be desk or wall mounted. The preference is wall mounted with the

cables dressed to a cable channel. Remember to leave space for access to the recovery

button. See section 7.7.6.