28

ENGLISH

– When the lamp life becomes less than 100 hours and the unit is still on, the remaining lamp life is displayed on the screen

automatically.

– When the lamp life becomes less than 5 hours, the remaining lamp life is displayed on the screen .

To clear the warning, press the

MENU

key.

– When the lamp life has expired (Lamp Life 0 HOURS), the unit will be immediately turned off, and the WARNING indicator will

light up in red.

❖

Initialize the Lamp Life

If the lamp is replaced to new one, follow this procedure to reset (initialize) the lamp life.
Refer to "Replacing Lamp Unit". (

☞

P.29)

1.

Connect the AC power cord after replacing lamp unit. (

☞

P.8)

2.

Press the

POWER ON

key on the remote controller or the

POWER

key on the projector.

The following message appears for 120 seconds.

3.

Select “Yes”, using the

1 / 2

keys.

4.

Press the

ENTER

key . The lamp life indicator is now initialized.