Flow control – Monarch Instrument 9402 User Manual

Page 91

Advertising
background image

Flow Control

To change the setting, follow steps 1 through 6 at the
beginning of this chapter. Then follow the steps below.

1. Press

2

until you see

DIAG COMM

<

Flow Control

>

2. Press

6

. You will see the previous setting, for example

FLOW CONTROL

<

DTR

The flow control options are

None
XON/XOFF
DTR

3. Press

1

or

2

to display the flow control you need, then

press

6

.

NOTE: The XON character is 17. The XOFF character is

19. Flow control must be set to DTR for IBM
personal computers (unless you have software for
XON/XOFF).

You will see

DIAG COMM

<

Flow Control

>

4. Press

8

three times to return to the Main menu and

save your changes.

NOTE: The printer will not save your changes if you turn

it Off before returning to the Main menu.