Energized Parts Chart

* Condenser Fan Motor: The fan motor is wired through a fan cycle pressure control, therefore, it may cycle on and off.

CONTROL BOARD RELAYS

RELAY

1

2

3

3A

3B

LENGTH

WATER

PUMP

HOT GAS

VALVE

RELAY

COIL

COMPRESSOR

CONDENSER

FAN MOTOR

of “ON” TIME

INITIAL START-UP/

START UP AFTER

AUTO SHUT-OFF:

1. Pressure

Equalization

OFF

ON

OFF

OFF

OFF

15

Seconds

2. Refrigeration
System Start-up

OFF

ON

ON

ON

ON

5

Seconds

FREEZE

SEQUENCE:

3. Pre-Chill

OFF

OFF

ON

ON

ON

30

Seconds

4. Freeze

ON

OFF

ON

ON

ON

Until 7 sec.

water contact

with ice

thickness

probe

HARVEST

SEQUENCE:

5. Harvest

OFF

ON

ON

ON

ON

Bin switch

activation

AUTOMATIC SHUT-

OFF:

6. Auto Shut-Off

OFF

OFF

OFF

OFF

OFF

Until

bin switch

re-closes

Advertising