Safety Limit #2

Harvest time exceeds 3.5 minutes for 3 consecutive harvest cycles.

Because there are many possible external problems,do not limit your diagnosis to only the items listed in
these charts.

Possible Cause

Check/Correct

Improper installation

See “Installation Instructions” Section 2 of this manual

Water system

Water area (evaporator) dirty

Water freezing behind evaporator

Low water pressure (20 psi minimum.)

Loss of water from sump area

Clogged water distribution tube

Dirty/defective water float valve

Defective water pump

Electrical system

Ice thickness probe out of adjustment

Ice thickness probe dirty

Bin switch defective

Premature harvest

Refrigeration system

Non-Manitowoc components

Improper refrigerant charge

Defective hot gas valve

TXV flooding (check insulation and bulb mounting)

Defective fan cycling control