Q130 Water Distribution Tube Removal

•

Loosen the two thumbscrews, which secure the
distribution tube.

•

Lift the distribution tube up off the thumbscrews.

Disassembly

•

Twist the barbed end until the tab lines up with the
keyway.

•

Pull the inner tube end outward.

Q130 Water Distribution Tube Disassembly

E. Remove the Float Valve

•

Turn the splash shield counterclockwise one or two
turns.

Float Valve Removal

•

Pull the float valve forward and off the mounting
bracket.

•

Disconnect the water inlet tube from the float valve at
the compression fitting.

•

Remove the cap and filter screen for cleaning.

THUMBSCREW

REMOVE ICE

THICKNESS PROBE

THUMBSCREW

DISTRIBUTION

TUBE

TAB

KEYWAY

FLOAT VALVE

BRACKET

COMPRESSION

FITTING

CAP AND

FILTER SCREEN

SHUT-OFF VALVE

SPLASH SHIELD

FLOAT