Section 4

Maintenance

Part Number 000001130 12/08

4-3

Q130 Models

Q130 Water Distribution Tube Removal

Loosen the two thumbscrews, which secure the
distribution tube.

Lift the distribution tube up off the thumbscrews.

Disassembly

Twist the barbed end until the tab lines up with the
keyway.

Pull the inner tube end outward.

Q130 Water Distribution Tube Disassembly

E. Remove the Float Valve

Turn the splash shield counterclockwise one or two
turns.

Float Valve Removal

Pull the float valve forward and off the mounting
bracket.

Disconnect the water inlet tube from the float valve at
the compression fitting.

Remove the cap and filter screen for cleaning.

THUMBSCREW

REMOVE ICE

THICKNESS PROBE

THUMBSCREW

DISTRIBUTION

TUBE

TAB

KEYWAY

FLOAT VALVE

BRACKET

COMPRESSION

FITTING

CAP AND

FILTER SCREEN

SHUT-OFF VALVE

SPLASH SHIELD

FLOAT