Maintenance

Section 4

4-4

Part Number 000001130 12/08

F. Remove the Water Trough

•

Apply downward pressure on the siphon tube and
remove from the bottom of the water trough.

•

Remove the upper thumbscrew.

•

While supporting the water trough remove the two
thumbscrews from beneath the water trough.

•

Remove the water trough from the bin area.

G. Remove the ice damper.

Q130

•

Grasp left side of ice damper and apply pressure
against the right-hand ice damper mounting bracket.

•

Pull forward on the ice damper until the left-hand
mounting pin disengages.

Installation

•

Grasp the right side of ice damper and place left
hand pin in the mounting bracket.

•

While applying pressure against the left-hand
mounting bracket push the damper until the right-
hand mounting pin engages.

Q210/Q270

•

Grasp ice damper and apply pressure toward the left
hand mounting bracket.

•

Apply pressure to the right hand mounting bracket
with thumb.

•

Pull ice damper forward when the right hand ice
damper pin disengages.

Installation

•

Place ice damper pin in left hand mounting bracket
and apply pressure toward the left hand mounting
bracket.

•

Apply pressure to the right hand mounting bracket
with thumb.

•

Push ice damper toward evaporator until right hand
damper pin engages.

REMOVE

SIPHON TUBE

UPPER

THUMBSCREW

LOWER

THUMBSCREWS