Maintenance

Section 4

4-2

Part Number 000001130 12/08

C. Remove the Ice Thickness Probe

Compress the side of the ice thickness

probe near the top hinge pin and remove it
from the bracket.

Ice Thickness Probe Removal

NOTE: At this point, the ice thickness probe can easily
be cleaned. If complete removal is desired follow the ice
thickness probe wire to the bulkhead grommet (exit
point) in the back wall. Pop the bulkhead grommet out of
the back wall by inserting fingernails or a flat object
between the back wall and the grommet and prying
forward. Pull the bulkhead grommet and wire forward
until the connector is accessible, then disconnect the
wire lead from the connector.

Ice Thickness Probe Cleaning

Mix a solution of Manitowoc ice machine cleaner and
water (2 ounces of cleaner to 16 ounces of water) in
a container.

Soak the ice thickness probe a minimum of 10
minutes.

Clean all ice thickness probe surfaces and verify the ice
thickness probe cavity is clean. Rinse thoroughly with
clean water, then dry completely. Incomplete rinsing and
drying of the ice thickness probe can cause premature
harvest.

D. Remove the Water Distribution Tube

Q210/Q270 Models

Q210/Q270 Water Distribution Tube Removal

Loosen the two thumbscrews, which secure the
distribution tube.

Lift the right side of the distribution tube up off the
locating pin, then slide it back and to the right.

Disassembly

Twist both of the inner tube ends until the tabs line up
with the keyways.

Pull the inner tube ends outward.

Q210/Q270 Water Distribution Tube Disassembly

ICE THICKNESS

PROBE

COMPRESS SIDES OF ICE

THICKNESS PROBE

! Caution

Do not force this removal. Be sure the locating pin is
clear of the hole before sliding the distribution tube
out.

1. LIFT UP
2. SLIDE BACK
3. SLIDE TO RIGHT

DISTRIBUTION
TUBE

THUMBSCREW

THUMBSCREW

LOCATING
PIN

3

2

1

INNER TUBE

TAB

KEYWAY

INNER TUBE