Changing Channel Parameters

The channel parameters include the interface type and its options, voice and fax settings,
billing and security, and voice communications for the country and region in which the
MVP120 is operating. The Channel Setup dialog box, accessed by clicking Voice Channels
on the Setup menu, has four tabs that display the following categories of channel information
-- Interface, Voice/Fax, Billing/Misc, and Regional.

Interface Tab

Check with your in-house telephone personnel to verify whether your local PBX dial signaling
is Pulse or DTMF (tone). Select the Regeneration option accordingly.

In the Inter Digit Time box, enter the maximum amount of time between dialed digits in
milliseconds that the unit will wait before mapping the dialed digits to an entry in the Phone
Directory Database. If too much time elapses between digits, the wrong numbers will be
mapped and you will hear a rapid busy signal. If this happens, hang up and dial again. The
default setting is 2 seconds.

In the Flash Hook Timer box, enter the amount of time the duration of flash hook signals
output on the interface. The default setting is 600 milliseconds.

The Ring Count FXO box enables you to set the maximum number of rings output on the
FXO interface before hanging up and releasing the line to another call. The default setting is
2 rings.

Note: Zero (0) means no incoming calls will be answered.

The Message Waiting Light check box must be selected on the originating and answering
voice channel. This enables the number dialed to connect you to the appropriate voice
channel, then output that number on the voice channel.