7. connecting the battery – Miller Electric 600 X User Manual

Page 29

Advertising
background image

OM-4428 Page 25

5-6. Activating The Dry Charge Battery (If Applicable)

!

Always wear a face shield,

rubber gloves and protective

clothing when working on a

battery.

Remove battery from unit.
1

Vent Caps

2

Sulfuric Acid Electrolyte

(1.265 Specific Gravity)

3

Well

Fill each cell with electrolyte to

bottom of well (maximum).

!

Do not overfill battery cells.

Wait ten minutes and check electro-

lyte level. If necessary, add electro-

lyte to raise to proper level. Reins-

tall vent caps.
4

Battery Charger

!

Read and follow all instruc-

tions supplied with battery

charger.

Charge battery for 12 minutes at 30

amperes or 30 minutes at 5 am-

peres. Disconnect charging cables

and install battery.

.

When electrolyte is low, add
only distilled water to cells to

maintain proper level.

1

Tools Needed:

2

4

30 A For 12 Minutes

5 A For 30 Minutes

OR

+

3

drybatt1 6/05 − S-0886

5-7. Connecting The Battery

1/2 in

+

!

Connect negative (−) cable last.

Tools Needed:

Ref. 215 664 / 803 605 / S-0756-C

.

Reinstall cover after connecting battery.

Advertising