3. remote amperage control on cc models (optional), 4. weld control/arc condition information label, And 6-3 – Miller Electric 600 X User Manual

Page 36

Advertising
background image

OM-4428 Page 32

6-3. Remote Amperage Control On CC Models (Optional)

1

Remote Amperage Adjust

Receptacle RC13

Connect optional remote control to

RC13 (see Section 5-11).

Example: Combination Remote Amperage Control (Stick)

Adjust Optional Remote Control

Set Switches

Set Range

Set Control

Ref. 154 862-A / Ref. 215 663 / 803 602

In Example:

Range = 115 to 330 A DC

Percentage Of Range = 50%

Max = About 240 A DC (50% of 150 to 330)

Max (240 A DC)

Min (84 A DC)

1

6-4. Weld Control/Arc Condition Information Label

.

Set weld controls as shown to
achieve softer or stiffer arc condi-

tions for different applications.

212 944-A