5-8. Engine Prestart Checks

.

Check all engine fluids daily.

Engine must be cold and on a level surface.

Unit is shipped with 20W break-in oil. The

Automatic shutdown system stops engine if

oil pressure is too low or coolant tempera-

ture is too high.

.

This unit has a low oil pressure shut-
down switch. However, some condi-

tions may cause engine damage before

the engine shuts down. Check oil level

often and do not use the oil pressure

shutdown system to monitor oil level.

Follow run-in procedure in engine manual.

If unburned fuel and oil collect in exhaust

pipe during run-in, see Section 13.

Fuel

NOTICE − Do not use gasoline. Gasoline

will damage engine.

Add fresh diesel fuel before starting to pre-

vent air from entering the fuel system (see

engine maintenance label for fuel specifica-

tions). Leave filler neck empty to allow room

for expansion.

Do not run out of fuel or air may enter fuel

system and cause starting problems. See

engine manual to bleed air from fuel system.

Oil
After fueling, check oil with unit on level sur-

face. If oil is not up to full mark on dipstick,

add oil (see maintenance label).

.

To improve cold weather starting:
Use optional Starting Aid switch (see

Section 6-1 or 7-1).

Keep battery in good condition. Store

battery in warm area.

Use fuel formulated for cold weather

(diesel fuel can gel in cold weather).

Contact local fuel supplier for fuel in-

formation.

Use correct grade oil for cold weather

(see Section 9-1 or 10-1).

Full

Ref. 803 657 / 803 658

Diesel

Full

Diesel

Full

Deutz F4L2011 Engine

Deutz F3L912 Engine

Full