Miller Electric 600 X User Manual
Page 47
OM-4428 Page 43
9-2. Routine Maintenance (Deutz F4L2011-Powered Units)
!
Stop engine before maintaining.
.
See Engine Manual and Maintenance Label
for important start-up, service, and storage
information. Service engine more often if
used in severe conditions.
Recycle engine
fluids.
n = Check
Z = Change
~ = Clean
l = Replace
* To be done by Factory Authorized Service Agent
Reference
Every
8
Hours
FUEL
WATER
n Fuel/Water Separator
n Fuel Level
n Oil Level
~ Oil, Fuel Spills
Every
50
Hours
~ Weld Terminals
Every
100
Hours
~ Battery Terminals
n Air Cleaner Hoses
n L’élément du filtre à air
Every
250
Hours
1/2 in.
(13 mm)
Engine
Manual,
l Unreadable Labels
n Fan Belt Tension
~ Cooling System
n~Spark Arrestor
Every
500
Hours
nl Weld Cables
Every
1000
Hours
Engine
Manual
Z Oil
Z Oil Filter
Z FuelFilter
Manual
OR
SLUDGE
FUEL
n~ Slip Rings*
nl Brushes*
~ Inside Unit
nValve Clearance*
~ Drain Sludge
Every
3000
Hours
~ Injectors*
Every
6000
Hours
or 5
Years
nl Engine Timing Belt