OM-4428 Page 60

Trouble

Remedy

Low CV weld output.

Set Ampere Range switch to highest range.

Increase Voltage/Amperage Adjust Control setting.

Min or max CV weld output only.

Check position of Voltage/Amperage Adjust control and Voltage/Amperage Adjust switch.

Repair or replace remote control device.

Have Factory Authorized Service Agent check Amperage/Voltage Adjust Control R1, and field current

regulator board PC1.

C. Standard Generator Power

Trouble

Remedy

No generator power output at ac recep-

tacles; weld output okay.

Reset receptacle supplementary protectors.

Reset GFCI receptacle.

No generator power or weld output.

Disconnect equipment from generator power receptacles during start-up.

Check fuses F1 and F2, and replace if open (see Section 9-8 or 10-9). Have Factory Authorized Service

Agent check integrated rectifier SR1, capacitor C9, and the rotor.

Reset supplementary protector CB12. Have Factory Authorized Service Agent check diode D1 .

Have Factory Authorized Service Agent check brushes and slip rings, and field excitation circuit.

High output at generator power ac re-

ceptacles.

Check engine speed, and adjust if necessary.

Have Factory Authorized Service Agent adjust generator power field current resistor R3.

Low output at generator power ac recep-

tacles.

Check engine speed, and adjust if necessary.

Check fuse F1, and replace if open (see Section 9-8 or 10-9). Have Factory Authorized Service Agent

check integrated rectifier SR1, resistor R3, and capacitor C9.

D. Optional Three-Phase Generator Power (CC/CV Models Only)

Trouble

Remedy

No or low output at optional three-

phase generator/receptacle RC5.

Place Process/Contactor switch in Weld Terminals Always On - Stick position (see Section 7-3).

Reset supplementary protector CB7(see Section 8-2).

Reset supplementary protector CB5 (see Section 9-8 or 10-9).

Check engine weld/power speed, and adjust if necessary (see Section 9-6 or 10-6).

Have Factory Authorized Service Agent check brushes and slip rings, and field current regulator board

PC1.

High output at optional three-phase

generator/receptacle RC5.

Check engine weld/power speed, and adjust if necessary (see Section 9-6 or 10-6).

Have Factory Authorized Service Agent check field current regulator board PC1, and PC1 voltage

feedback circuit.

Erratic output at optional three-phase

generator/receptacle RC5.

Have Factory Authorized Service Agent check brushes and slip rings, and field current regulator board

PC1.