Fuel consumption, Duty cycle and overheating, 5. fuel consumption – Miller Electric Big Blue 452P User Manual

Page 24: 6. duty cycle and overheating

Advertising
background image

OM-496 Page 18

Return To Table Of Contents

4-5.

Fuel Consumption

The curve shows typical fuel use
under weld or power loads.

199 032

0.00

0.25

0.50

0.75

1.00

1.25

1.50

1.75

2.00

0

50

100

150

200

250

300

350

400

DC WELD AMPERES AT 100% DUTY CYCLE

US GAL/HR.

IDLE

Continuous Welding

4-6.

Duty Cycle And Overheating

Duty Cycle is percentage of 10 min-
utes that unit can weld at rated load
without overheating.

Y

Exceeding duty cycle can
damage unit and void
warranty.

100% Duty Cycle At 300 Amperes

199 140

WELD

AMPERES

% DUTY CYCLE

Advertising