Routine maintenance, 2. routine maintenance, Every 8 h – Miller Electric Big Blue 452P User Manual

Page 48: Every 50 h, Every 100 h, Every 250 h, Every 500 h

Advertising
background image

OM-496 Page 42

Return To Table Of Contents

9-2.

Routine Maintenance

The engine oil/filter and fuel injector maintenance intervals are different for the Perkins
404.22 and 3.152 engines (see maintenance schedule following).

Note

Follow the storage procedure in the engine owner’s manual if the unit will not be used for an
extended period.

Note

Recycle engine

fluids.

Y

Stop engine before maintaining.

.

See Engine Manual and Maintenance
Label for important start-up, service,
and storage information. Service unit
more often if used in severe conditions.

*

To be done by Factory Authorized
Service Agent.

Every 8 h

Check Fluid
Levels. See
Section 5-7.

Wipe

Up

Spills.

Drain Water

From Fuel

System.

OIL
Full

FUEL

WATER

Coolant

Full

Every 50 h

Clean Air Filter.

See Section 9-3.

Clean And

Tighten

Weld

Terminals.

Every 100 h

Clean And

Tighten
Battery

Connections.

Check air cleaner
hoses for cracks
and loose clamps.

Every 250 h

Change Oil. See

Section 9-7.

Change Oil Filter.

See Section 9-7.

Replace

Unreadable

Labels.

Check And

Clean Spark

Arrestor. See

Section 9-4.

Every 500 h

Repair Or

Replace

Damaged

Cables.

1/2 in.

(13 mm)

Check Belt

Tension.

Advertising