5-11. Connecting To Remote 14 Receptacle RC14 On CC/CV Models

Socket*

Socket Information

24 VOLTS AC

A

24 volts ac. Protected by circuit
breaker CB5.

24 VOLTS AC

B

Contact closure to A completes
24 volt ac contactor control
circuit.

C

Output to remote control:+10
volts dc in MIG or Stick mode;
0 to +10 volts dc in TIG mode.

New! LDR-14 long

distance remote

(includes 120 V

REMOTE

OUTPUT

D

Remote control circuit common.

distance remote

(includes 120 V

receptacle)

OUTPUT

CONTROL

E

DC input command signal: 0 to
+10 volts from min. to max. of
remote control with Voltage/
Amperage Adjust control at
max.

OR

115 VOLTS AC

I

115 volts, 10 amperes, 60 Hz
ac. Protected by circuit breaker
CB6.

J

Contact closure to I completes
115 volt ac contactor control
circuit.

802 311

GND

K

Chassis common.

NEUTRAL

G

Circuit common for 24 and 115
volt ac circuit.

*The remaining sockets are not used.