SECTION 5 − INSTALLATION

install3 6/03 − Ref. 800 652 / Ref. 800 477-A / 803 274

Y

Always securely fasten weld-
ing generator onto transport
vehicle or trailer and comply
with all DOT and other applica-
ble codes.

Y

Always ground generator
frame to vehicle frame to pre-
vent electric shock and static
electricity hazards.

Y

If unit does not have GFCI re-
ceptacles, use GFCI-protected
extension cord.

.

See Section 5-3 for mounting in-
formation.

Grounding:

1

Equipment Grounding Terminal
(On Front Panel)

2

Grounding Cable (Not Supplied)

3

Metal Vehicle Frame

Connect cable from equipment
ground terminal to metal vehicle
frame. Use #10 AWG or larger insu-
lated copper wire.

Electrically bond generator frame to
vehicle frame by metal-to-metal contact.

GND/PE

1

2

3

18 in

(460 mm)

18 in

(460 mm)

18 in

(460 mm)

18 in

(460 mm)

18 in

(460 mm)

Movement

Airflow Clearance

5-1.

Installing Welding Generator (See Sections 5-2 And 5-3)

OR

OR

Grounding

Y

Bed liners, shipping skids, and some running
gears insulate the welding generator from the
vehicle frame. Always connect a ground wire
from the generator equipment grounding termi-
nal to bare metal on the vehicle frame as shown.