Installing a second dc power module, Warning, Avertissement – Motorola 3460 User Manual

Page 43: Warnung

Advertising
background image

3460 Fast’R

1-29

Installing a Second DC Power Module

You can install a second DC power module, while the AccessWay is
operating, as follows.

Installing a Second DC Power Module

Step

Action

1.

Warning

The AccessWay enclosure power module
should be installed and removed only by a
trained service person.

Avertissement

Le module d’alimentation électrique de
l’enceinte AccessWay doit être installé et
retiré par un réparateur expérimenté.

Warnung

Ein- und Ausbau des AccessWay
Schaltschranks ist von einem geschulten
Wartungstechniker vorzunehmen.

2.

Remove the blank panel that covers the right power module slot
by loosening the screws at the top and bottom (Figure 1-14).

3.

Slide the second power module into the right AccessWay power
module slot. Ensure that its front rail is flush with the adjacent
power module rail.
Tighten the power module screws.

4.

Optionally, connect a remote alarm monitoring device to the
AccessWay ALARM 2 terminals, to alert you to a fault in the
DC output voltage. To do so, refer to the “Connecting the
AccessWay to DC Power Supply” section on page 1-25.

5.

Verify that the LEDs on the power modules are lit. The LEDs
indicate the presence of input voltage and the status of output
voltage.

Advertising