OM-1327 Page 12

3-3. Volt-Ampere Curve

217 443-A

1

Normal Volt-Ampere Curves

The volt-ampere curves show the

normal minimum and maximum

voltage and amperage output

capabilities of the welding power

source. Curves of other settings fall

between the curves shown.

MAXVOLTS

MINVOLTS

0

50

100

150

200

250

300

350

0

10

20

30

40

50

60

70

80

90

VOL

TAGE

AMPERAGE

3-4. Connecting To Weld Output Terminals

803 778-A

!

Turn off power before connecting to

weld output terminals.

!

Failure to properly connect weld

cables may cause excessive heat

and start a fire, or damage your ma-

chine.

1

Weld Output Terminal

2

Supplied Weld Output Terminal Nut

3

Weld Cable Terminal

4

Copper Bar

Remove supplied nut from weld output ter-

minal. Slide weld cable terminal onto weld

output terminal and secure with nut so that

weld cable terminal is tight against copper

bar. Do not place anything between weld

cable terminal and copper bar. Make

sure that the surfaces of the weld cable

terminal and copper bar are clean.

Tools Needed:

3/4 in. (19 mm)

4

2

3

Do not place

anything between

Correct Installation

Incorrect Installation

1

weld cable terminal

and copper bar.