Miller Electric MILLERMATIC 350P User Manual

Page 49

Advertising
background image

.

A complete Parts List is available at www.MillerWelds.com

OM-1327 Page 45

SC-187 212-A

.

All directions are in reference to the
front of the unit. All circuitry referred to

is located inside the unit.

S

Help 0

Indicates overheating on left side of unit

(displays flash between OVER TEMP and

HELP 0). Unit will shutdown until internal

temperature drops within operational range.

S

Help 1

Turn off primary input power and check input

voltage per primary voltage rating of welder,

and correct if necessary. If HELP 1 persists,

this Indicates a communication error

between control board PC1 and user

interface board. Contact nearest Factory

Authorized Service Agent.

S

Help 2

Indicates overheating on right side of unit

(displays flash between OVER TEMP and

HELP 2). Unit will shutdown until internal

temperature drops within operational range.

S

Help 3

Indicates gun trigger was pulled and held

during power up. Release gun trigger and

clear fault condition. Also, this display can

Indicate no open circuit voltage detected

when gun trigger is pulled and no arc

detected within 3 seconds. Turn off primary

input power and contact a Factory

Authorized Service Agent.

S

Help 4

Indicates gun trigger was pulled and held for

2 minutes without a welding arc established

or there is a direct short between contact tip

or wire and the workpiece. Release gun

trigger and clear fault condition.
S

Help 5

Indicates a malfunction in wire feed system

and/or drive motor overcurrent condition.

Check for proper spool brake adjustment or

obstructions in wire feed system. Clean or

replace liner, wire guides, or contact tip.
S

Help 6

Indicates a malfunction in wire feed system

and/or external drive motor overcurrent con-

dition (spool gun or push-pull gun). Check for

proper spool brake adjustment or

obstructions in wire feed system. Clean or

replace liner, wire guides, or contact tip.
S

Help 7

Indicates input voltage malfunction (voltage

too high or too low) causing unit to

automatically shut down. Turn off input

primary power and check input voltage per

primary voltage rating of welder. Unit will

operate once input voltage is within

specification and power to unit is turned off

and back on.
S

Help 8

Indicates a malfunction in the secondary

power circuit of the unit. Check control board

PC1, and primary and secondary

connections.

S

Help 9

Indicates a malfunction in Pulse MIG

function. Check connection between pulse

board and user interface board. Replace

pulse board, if necessary.
S

Help 10

Indicates a trigger error when two gun

triggers are activated at the same time.

Release gun triggers to clear error.
S

Help 11

Indicates a tach error when tach feedback

signal is not present. Release and press gun

trigger to reset tach signal. If error continues,

contact a Factory Authorized Service Agent.
S

Tip Save

Indicates contact tip is directly shorted to

workpiece. Arc shuts off in this condition,

and message resets when tip is not touching

workpiece and gun trigger is released.
S

MM 350P

When unit is turned on, this display indicates

that pulse option is installed and operational.
S

MM 350

When unit is turned on, this display indicates

that unit is either a MIG only machine or

pulse option is installed but not operational.
S

Jog XXX (Wire Feed Speed)

Indicates trigger is pressed, but no arc is

detected. Wire feed speed goes to Jog wire

feed speed after 3 seconds.

Advertising