3-14. Selecting Input Voltage (200/230/460 Volt Models Only)

803 539-C / 804 042-A

!

Turn Off welding power

source, disconnect input

power, and check voltage on

input capacitors according

to Section 6-3 before

proceeding.

.

Check input voltage available
at site.

.

Incorrect linking can damage
unit and void the warranty.

1

Voltage Selection View

Window

Check voltage selected in unit.

Changing selection is only neces-

sary if selected value does not

match available input voltage.
2

Relinking Board PC6

3

Mounting Screws

4

Receptacle RC23

(Connection For 230 VAC

Input Power)

5

Receptacle RC46

(Connection For 460 VAC

Input Power)

Move relinking board as needed

and connect plug PLG32 (in unit) to

RC23 or RC46 according to input

power voltage.

Tools Needed:

5/16 in.

.

Be sure to reinstall all four screws
securing relinking board in place.

2

3

4

3

5

1