3-15. Serial Number And Rating Label Location

The serial number and rating information for this product is located on back. Use rating label to determine input power requirements and/or rated output.

For future reference, write serial number in space provided on back cover of this manual.

3-16. Selecting A Location And Connecting 3-Phase Input Power

Ref. 803 543-E / 803 766-A

!

Installation must meet all National and

Local Codes - have only qualified

persons make this installation.

!

Disconnect and lockout/tagout input

power before connecting input

conductors from unit.

!

Always connect green or green/yellow

conductor to supply grounding terminal

first, and never to a line terminal.

!

Warning: This unit is either a

200/230/460 ac input voltage model or

460/575 ac input voltage model. See

rating label on unit and check voltage

available at site to be sure it matches

the voltage specified on the rating

label.

1

Input Power Cord Strain Relief

2

Input Power Cord

3

Disconnect Device (switch shown in

the OFF position)

4

Green Or Green/Yellow Grounding

Conductor

5

Disconnect Device Grounding Terminal

6

Input Conductors (L1, L2 And L3)

7

Disconnect Device Line Terminals

Connect green or green/yellow grounding

conductor to disconnect device grounding

terminal first.

Connect input conductors L1, L2, and L3 to

disconnect device line terminals.

8

Over-Current Protection

Select type and size of over-current

protection using Section 3-13 (fused

disconnect switch shown).

Close and secure door on disconnect device.

Remove lockout/tagout device, and place

switch in the On position.

Tools Needed:

2

1

Rear Panel

18 in. (457 mm)

for airflow

!

Do not move or operate

unit where it could tip.

= GND/PE Earth Ground

3

3

4

5

7

6

8

L1

L2

L3