5-7. Connecting The Battery

1/2 in

+

Y Connect Negative (−) Cable Last.

Tools Needed:

802 168-E / Ref. 202 705 / 802 313 / S-0756-C

.

Reinstall cover after connecting battery.

ether1 7/96 − 153 382-A / Ref. 202 705

Y Stop engine.
Y Improper handling or expo-

sure to ether can harm your

health. Follow manufactur-

er’s safety instructions on

cylinder.

Y Do not use Ether Starting Aid

while engine is running.

Remove rubber access plug from

cover.
1

Ether Cylinder

2

Nozzle

Remove cover and clean cylinder

nozzle.
3

Clamp

4

Fitting

5

Cap

6

Valve

Remove cap and clean fitting.

Install cylinder on fitting. Tighten

clamp.

.

After installing cylinder, wait at
least 10 minutes before using
to let ether particles settle and
prevent atomizer plugging.

Put cap on fitting when cylinder is

removed.
Reinstall plug in cover.