7-4. Remote Voltage/Amperage Control On CC/CV Models (Optional)

1

Remote 14 Receptacle RC14

Connect optional remote control to

RC14 (see Section 5-13).

0774 / Ref. 192 895-A / 802 311-A

Example: Combination Remote Amperage Control (Stick)

In Example:

Process = Stick (Using Remote On/Off)

Range = 125 to 320 A DC

Min = 125 A DC

Max = 320 A DC

Adjust Optional Remote Control

Set V/A

Adjust Switch

Set Range

Control Not

Used In Remote

Stick Mode

Max (320 A DC)

Min (125 A DC)

Set Remote

Process

Example: Combination Remote Amperage Control (TIG)

In Example:

Process = TIG (Using Remote On/Off)

Range = 40 to 200 A DC

Percentage Of Range = 50%

Min = 40 A DC

Max = About 120 A DC (50% of 40 to 200)

Adjust Optional Remote Control

Set V/A

Adjust Switch

Set Range

Set Control

Max (120 A DC)

Min (40 A DC)

Set Remote

Process