3. remote amperage control on cc models (optional), 4. weld control/arc condition information label, See section 6-4 – Miller Electric Big Blue 402D User Manual

Page 42: And 6-3)

Advertising
background image

OM-495 Page 36

Return To Table Of Contents

6-3. Remote Amperage Control On CC Models (Optional)

1

Remote Amperage Adjust

Receptacle RC13

Connect optional remote control to

RC13 (see Section 5-12).

0774 / Ref. 154 862-A / Ref. 181 711-A / 802 311-A

Example: Combination Remote Amperage Control (Stick)

In Example:

Range = 125 to 320 A DC

Percentage Of Range = 50%

Max = About 223 A DC (50% of 125 to 320)

Adjust Optional Remote Control

Set Switches

Set Range

Set Control

Max (223 A DC)

Min (87 A DC)

1

6-4. Weld Control/Arc Condition Information Label

.

Set weld controls as shown to
achieve softer or stiffer arc condi-
tions for different applications.

212 944-A

Advertising