7-2. Description Of Front Panel Controls For CC/CV Models (See Section 7-1)

Engine Starting Controls
1

Magnetic Shutdown Switch

Use switch during start-up to bypass engine

shutdown system. System stops engine if oil

pressure is too low or engine temperature is

too high.
2

Starting Aid Switch (Optional)

Use switch to energize starting aid for cold

weather starting.
Deutz F4L2011-powered units use a glow

plug starting aid. Push switch up for 60 sec-

onds to operate the glow plug before cranking

engine (see starting instructions following).
Deutz F3L912-powered units use an ether

starting aid system. Push switch up and re-

lease while cranking engine to release ether

(see starting instructions following).
3

Engine Control Switch

Use switch to start engine, select engine

speed (if unit has auto idle option), and stop

engine.
In Run position, engine runs at weld/power

speed. In Run/Idle position (optional), engine

runs at idle speed at no load and weld speed

with load applied.
To Start:

.

If engine does not start, let engine come
to a complete stop before attempting re-
start.

Above 325 F (05 C): turn Engine Control

switch to Start while pressing Shutdown

switch. Release Engine Control switch when

engine starts. Continue holding Shutdown

switch until engine indicator lights go out.
Below 325 F (05 C) using optional starting

aid switch:

Deutz F4L2011-powered units − Turn Engine

Control switch to Run/Idle position. Push

Starting Aid switch up for 60 seconds. While

still holding Starting Aid switch, press Mag-

netic Shutdown switch and turn Engine Con-

trol switch to Start. Release Engine Control

switch and Starting Aid switch when engine

starts. Continue holding Shutdown switch un-

til engine indicator lights go out.

Deutz F3L912-powered units − Press Mag-

netic Shutdown switch and turn Engine Con-

trol switch to Start. While cranking engine,

push Starting Aid switch up and release. Re-

lease Engine Control switch when engine

starts. Continue holding Shutdown switch un-

til engine indicator lights go out.
To Stop: turn Engine Control switch to Off

position.

Engine Indicator Lights
4

Battery Charging Light

Light goes on if engine alternator is not charg-

ing battery. Engine continues to run.
Y Stop engine and fix trouble if Battery

Charging light goes on.

5

Engine Temperature Light

Light goes on and engine stops if engine oil

temperature is above 266

°

F (130

°

C).

Y Stop engine and fix trouble if Engine

Temperature light goes on.

6

Engine Oil Pressure Light

Light goes on and engine stops if oil pressure

is below 22 psi (150 kPa). Light goes on mo-

mentarily during start-up but goes out when

engine reaches normal oil pressure.
Y Stop engine and fix trouble if Engine

Oil Pressure light stays on after start-

up.

7

Fuel Light

Fuel light is not active on this model.
8

Engine Hour Meter

Engine Gauges

.

To read gauges and engine indicator
lights with engine off, turn Engine Control
switch to Run/Idle and press Magnetic
Shutdown switch (see Section 11-1
).

9

Fuel Gauge

Use gauge to check fuel level.
To check fuel level when engine is not run-

ning, turn Engine Control switch to Run/Idle

position and press Magnetic Shutdown

switch.
10 Battery Voltmeter (Optional)
Use gauge to check battery voltage and moni-

tor the engine charging system. The meter

should read about 14 volts dc when the en-

gine is running, and about 12 volts dc when

the engine is stopped.
11 Engine Temperature Gauge (Optional)
Normal temperature is 212 - 239

°

F (100 -

115

°

C). If equipped with gauge option, engine

stops if temperature exceeds 270

°

F (132

°

C).

12 Engine Oil Pressure Gauge (Optional)
Normal pressure is 30 − 60 psi (206 − 414

kPa). If equipped with gauge option, engine

stops if pressure is below 20 psi (138 kPa).
Weld Controls
13 Process/Contactor Switch
See Section 7-3 for Process/Contactor

switch information.

14 Ampere Range Switch

Y Do not switch under load.
Use switch to select weld amperage range.

Use the lowest four ranges for Stick and TIG

welding. Read the upper set of numbers at

each range for Stick welding and the lower set

at each range for TIG welding.

Use the highest range for MIG welding and for

cutting and gouging (CAC-A).

For most welding applications, use lowest

amperage range possible to help prevent arc

outages.

15 Voltage/Amperage Adjust Control

With Process/Contactor switch in any Stick or

TIG setting, use control to adjust amperage

within range selected by Ampere Range

switch. With Process/Contactor switch in any

MIG position, use control to adjust voltage.

With Voltage/Amperage Adjust Switch in Re-

mote position, control limits the remote am-

perage in TIG mode, but has no effect in Stick

and MIG modes.

Weld output would be about 223 A DC with

controls set as shown (50% of 125 to 320 A).

.

The numbers around the control are for
reference only and do not represent an
actual percentage value.

16 Voltage/Amperage Adjust Switch And

Remote 14 Receptacle

Use switch to select front panel or remote

voltage/amperage control. For remote con-

trol, place switch in Remote position and con-

nect remote control to Remote 14 receptacle

RC14 (see Sections 5-13 and 7-4).

17 Polarity Switch (Optional)

Y Do not switch under load.
Use switch to change weld output. Select ei-

ther DC Electrode Positive (DCEP) or DC

Electrode Negative (DCEN).

Weld Meters

18 DC Voltmeter (Optional)

Voltmeter displays voltage at the weld output

terminals, but not necessarily the welding arc

due to resistance of cable and connections.

19 DC Ammeter (Optional)

Ammeter displays amperage output of the

unit.