Cf 220, Telco did outlet telco did outlet, Technical parameters related to did line – Multi-Tech Systems CF220 User Manual

Page 13

Advertising
background image

Chapter 2: Sample System

Multi-Tech Systems, Inc.

CF220 CallFinder User Guide

13

Step 2 Technical: Enter operating parameters of DID lines.

Each DID line has 3 user-specified technical parameters. You set them in the CallFinder software.

Power

48Vdc

Channel 2

Channel 1

Power

5Vdc

Ethernet

FXS/FXO DID

FXS/FXO DID

10/100

Channel Configuration: Channel 1

Max DID Digits

4

DID Start

wink

immediate

delay dial

Extension Port

FXS

FXO

Auto Attendant Delay

0

Receive Gain 100

Transmit Gain 100

Polarity

A

B

Update

Channel Configuration: Channel 2

Max DID Digits

4

DID Start

wink

immediate

delay dial

Extension Port

FXS

FXO

Auto Attendant Delay 2

Receive Gain 100

Transmit Gain 100

Polarity

A

B

Update

CF

220

(Rear)

Telco

DID

Outlet

Telco

DID

Outlet

of DID Line

Technical Parameters


Technical Parameters Related to DID Line

Parameter Value Comments
Max DID Digits

4

Number of digits received on DID line.

Polarity

try A

This is a trial-and-error setting. The DID line is a
twisted pair. Only when installed can you know
polarity. You determine the polarity by performance –
with wrong polarity, connections cannot be made.

DID Start

ask telco

Start mode varies with different implementations of
DID.