Telco did outlet, Pbx station port, Cf220 – Multi-Tech Systems CF220 User Manual

Page 15: Rear)

Advertising
background image

Chapter 2: Sample System

Multi-Tech Systems, Inc.

CF220 CallFinder User Guide

15

Step 3 Technical: Enter operating parameters of CallFinder channel (FXO)

Each of the CallFinder’s DID-channel modems has 4 user-specified parameters. You set them in the
CallFinder software.

Power

48Vdc

Channel 2

Channel 1

Power

5Vdc

Ethernet

FXS/FXO DID

FXS/FXO DID

10/100

Update

CF220

(Rear)

of CallFinder

DID-Channel Modem

Technical Parameters

Telco

DID

Outlet

Channel Configuration: Channel 1

Max DID Digits

4

DID Start

wink

immediate

delay dial

Extension Port

FXS

FXO

Auto Attendant Delay

0

Receive Gain 100

Transmit Gain 100

Polarity

A

B

Extension Mic Gain

8

Extension Speaker Gain

30

PBX

Station

Port


Technical Parameters Related to CallFinder’s Extension Port Line

Parameter Value Comments
Extension Port

FXO

Use FXO whenever CallFinder channel connects to
PBX station port.

Auto Attendant Delay

0
(in seconds)

Describes how long the CallFinder waits before
dialing. If set to 0, CallFinder calls as soon as PBX
dial tone is present. If no dial tone is present, the call
cannot be completed.

Extension Mic Gain

8

This describes the amplification of the sound input at
the local phone user’s mouthpiece microphone.

The default value is typically appropriate

.

This is a very sensitive parameter and mis-adjustment
can render the channel inoperable.

Adjust carefully and only if needed.

Extension Speaker Gain

30

This describes the amplification of the sound output at
the local phone user’s earpiece speaker.

The default value is typically appropriate

.

This is a very sensitive parameter and mis-adjustment
can render the channel inoperable.
Adjust carefully and only if needed.