Component testing information, Warning – Maytag AOES3030 User Manual

Page 10

Advertising
background image

Component Testing Information

!

WARNING

To avoid risk of electrical shook, personal injury or death: disconnect power to oven before servicing, unless
testing requires it.

16021875 Rev. 0

©2003 Maytag Appliances Company

10

Illustration Component

Test

Procedure

Results

Oven light socket

Test continuity of receptacle terminals.

Measure voltage at oven light.

Indicates continuity with bulb screwed in.

120 VAC, see wiring diagram for terminal
identification.
If no voltage is present at oven light
check wiring.

Bake element

Test continuity of terminals.

Test voltage to terminals.

Indicates continuity.

240 VAC

Broil element

Test continuity of terminals.

Test voltage to terminals.

Indicates continuity.

240 VAC

Convection element

Test continuity of terminals.

Test voltage to terminals.

Indicates continuity.

240 VAC

Convection motor fan

Verify supply voltage.
Check continuity of terminals, and
verify terminals are not shorted to
chassis.

120 VAC
Continuity

Convection fan will stay ON, when
oven door is opened.

Blower motor

Verify supply voltage.
Check continuity of terminals, and
verify terminals are not shorted to
chassis.

120 VAC
Continuity

Heraeus sensor

Measure resistance.

Approximately 1100

at room

temperature 75

º

F.

Opening

Hinge

Carefully open the hinge fully, and
insert a wooden dowel or screwdriver
bit into opening.
Remove top and bottom screws
securing hinge.
Slide hinge top towards rear of unit
and guide hinge out through frame
opening or storage drawer.

CAUTION

!

Do not place hands in hinge area when
oven door is removed. Hinge can snap
closed and pinch hands or fingers.

COM

NC

NO

Door lock switch

Switch connection in following
positions:
Unlocked
Locked


COM-NO=Open, COM-NC=Closed
COM-NO=Closed, COM-NC=Open

Controls

Verify proper operation.
31–308417–02–0 Fan control
31–31751801–0 Control limit


Open at 115°F, Closes at 155°F
Open at 260°F, Closes at 220°F

NC

NO

C

Door plunger switch

Remove switch from unit and measure
the following points:
C-NC
C NO



Plunger in infinite, Plunger out continuity.
Plunger in continuity, Plunger out infinite.

Advertising