Electronic Oven Control Options

LIGHT— Use to turn light on and off inside oven. Light
will automatically turn on when oven door is opened.

TIMER ON/OFF— Use to time any kitchen function or
cancel timer.

STOP TIME— Use to set delayed bake and delayed self
clean.

CLOCK — Use to set time of day.

OVEN CANCEL— Cancels any cooking or cleaning
function.

COOK TIME — Use to set timed or delayed baking.

BAKE— Use to set bake.

BROIL— Use to set broil

CLEAN— Use to set self-clean.

+

or

-

— Use to select temperature or time.

Special Oven Control Functions

Preheat Signal
After setting the oven to cook and selecting a
temperature, oven will preheat. When oven reaches set
temperature, a 1-second signal will sound.

End-of-Cycle Signal
When a timed cycle is complete, three long signals will
sound. End of cycle signal will continue to sound until
CANCEL is touched. If TIMER ON/OFF end-of-cycle
signal is sounding, touch TIMER ON/OFF.

Child Lockout
This is a safety feature used to prevent children from
accidentally programing oven. It disables electronic oven
control. Touch and hold BAKE and COOK TIME for 5
seconds. “OFF” will display where the temperature
normally appears. To reactivate control, press and hold
BAKE and COOK TIME pads for 5 seconds. Child
lockout feature must be reset after a power failure.

12-hour Automatic Cancel
This is a safety feature that prevents oven from continuing
to operate if it has been left on for over 12 hours. If a
cooking function continues longer than 12 hours without
any oven control options being touched, this feature turns
oven off. Any time an option is touched 12-hour
automatic cancel is reset.

Timer Signal
When time elapses, timer beeps 3 times then once every
10 seconds until cancelled.

Increasing

+

or

-

Pad Speed

When setting time and temperature, hold pad to
accelerate rate at which numbers increase or decrease.

Self-diagnostic System
Electronic range control has a self-diagnostic system.
Self-diagnostic system sounds a series of short, rapid
beeps and shows an "F-code" in display when there is a
problem.