Component Testing Information

!

WARNING

To avoid risk of electrical shook, personal injury or death: disconnect power to oven before servicing, unless
testing requires it.

©2003 Maytag Appliances Company

16021875 Rev. 0

13

Element Conditions

Relay drive requirements are defined as a percentage of on time based on a 60 second cycle.

Bake .......................First rise to temperature = 100% bake, 50% broil, then 100% bake, 25% broil
Broil........................100% broil, 0% bake
Clean ......................100% broil, 25% bake
Convection ............First rise to temperature = 100% bake, 50% broil, then 100% Convection element

For convection bake or convection broil refer to bake and broil specifications

Continuity is indicated as 100

Ω

and below. Each pad must be pressed to perform the following test.

J1 - 2

J1 - 20

J1 - 1

J1 - 6

J1 - 7

J1 - 5

J1 - 4

J1 - 3

J1-

14

J1-

13

J1-

12

J1-

11

J1-

10

J1-

9

J1-

8

J1-

16

J1-

18

J1-

19

BAKE BROIL

TIMER CLOCK

CLEAN

STOP
TIME

OVEN
LIGHT

CANCEL

SLEW
DOWN

SLEW
UP

COOK
TIME

Switch Matrix for AOES3030


J1 - 2

J1 - 20

J1 - 1

J1 - 6

J1 - 7

J1 - 5

J1 - 4

J1 - 3

J1

-1

4

J1

-1

3

J1

-1

2

J1

-1

1

J1

-1

0

J1

-9

J1

-8

J1

-1

6

J1

-1

8

J1

-1

9

BAKE
1

BROIL
1

TIMER CLOCK

CLEAN
1

CONV
1

CONV

BAKE

1

CONV

BROIL

1

STOP
TIME

OVEN
LIGHT

PANEL
LIGHT

CANCEL
1

SLEW
DOWN

SLEW
UP

COOK

TIME

1

Switch Matrix for AOCS3040

Control
Panel

Ribbon Cable

Pin 1 is located at the
bottom of the connector.

Top

Bottom