Warning, Installation instructions – Maytag AOES3030 User Manual

Page 24

Advertising
background image

A—4

16021875 Rev. 0

©2003 Maytag Appliances Company

Wall Oven and Cooktop Combination
Installation Specifications

Installer

NOTE: Save these instructions for local electrical

inspectors use.

Leave these instructions and other literature with
consumer for future reference.
Installations specified in these instructions are approved
for the AKT3000, AK2T30, AK2T36, AK2H30, AK2H36,
AKR3000 cooktops, and AKED3060, AKES3060
downdraft cooktops, above AOCS3040 and AOES3030
Amana wall ovens. Stacked and side-by-side wall oven
installation applies to Amana AOCS3040 and AOES3030
wall ovens only.
For additional individual unit requirements and clearances
refer to the installation instructions packaged with the wall
oven and cooktop.
All installations specified are for a 36" cabinet height,
23

1

/

2

" minimum depth, and 3

1

/

4

x 10" venting.

WARNING

!

To avoid property damage or personal injury,
information in these installation specifications must be
followed exactly.

Listed by Underwriter's Laboratories

AKED3060 or AKES3060 Downdraft
Cooktop above AOES3030 or AOCS3040
Wall Oven

Junction box location and 10

1

/

8

x 3

3

/

8

inch vent location

indicated in black.
A —

6 inches

B —

4

1

/

2

inches (from top of countertop)

C —

24 inches

D —

4

3

/

8

inches from top of countertop to top of vent

cutout

H —

28

1

/

2

inch wall oven cutout width

I

27

1

/

4

inch wall oven cutout height

J —

28

7

/

8

inch cooktop cutout width

K —

20

5

/

8

inch cooktop cutout depth

L —

4

1

/

2

inches from top of countertop to top of wall

oven cutout

C

C

C

Oven and Cooktop

junction box

installed in

adjacent cabinet

Centerline of cabinet
cutout

K

I

J

H

L

Installation Instructions

Advertising
This manual is related to the following products: