Models MT5600ZDX & ZDXV

Command: &Mn Communications Mode

Values:

n = 0

Defaults:

0

Description: &M0

Asynchronous mode.

&M1

Reserved—responds ERROR.

*&M0 selects direct asynchronous operation. Note that the command

sequence &M0\N0 selects normal buffered mode, but the command

sequence \N0&M0 selects direct mode. This is because the \N0 command

is analogous to the &Q6 command.

Command: &Qn Asynchronous Communications Mode

Values:

n = 0, 5, or 6

Defaults:

5

Description: &Q0

Asynchronous with no data buffering/no error

correction. Same as \N0.

&Q5

Asynchronous with data buffering/error correction.

Same as \N3.

&Q6

Asynchronous with data buffering/no error correc-

tion. Same as \N0.

Command: &Sn Data Set Ready (DSR) Control

Values:

n = 0 or 1

Default:

0

Description: &S0

Force DSR ON at all times.

&S1

DSR becomes active after answer tone is detected

(CD), and inactive after carrier tone is lost.

Command: $SBn Serial Baud Rate

(Modem DTE Speed; bps)

{ zdx only }

Values :

n = 300, 1200, 2400, 4800, 9600, 192000, 38400,

57600, 115200 (in bits per second)

Default:

56000

Description:

Example: $SB115200. Sets serial baud rate within a

host/server PC to 115,200 bps.

Command: &Tn

Test Commands

Values:

n = 0, 1, 3, 4, 5, 6, 7 or 8

Default:

None

Description: &T0

Abort. Stop any test in progress.

&T1

Starts Local Analog loop test.