Multitech V.90/K56FLEX MT5600ZDXV User Manual

Page 54

Advertising
background image

54

Models MT5600ZDX & ZDXV

S6

seconds 2–255

2

Sets the time the modem waits

after it goes off-hook before it

begins to dial the telephone num-

ber.

S7

seconds 1–255

50

Sets the time the modem waits

for a carrier signal before abort-

ing a call. Also sets the wait for

silence time for the @ dial mod-

ifier.

Register Unit

Range Default Description

S8

seconds 0–255

2

Sets the length of a pause caused

by a comma character in a dialing

command.

S9

1/10 sec 0–255

6 (0.6) Sets the time, in tenths of a

second, that the carrier must be

present before the modem con-

siders it valid and turns on the

RLSD.

S10

1/10 sec 1–255

14 (1.4) Sets the time, in tenths of a

second, that a carrier signal must

be lost before the modem discon-

nects.

S11

1 ms

50–255 95

Sets spacing and duration of dial-

ing tones.

S12

1/50 sec 50–255 50 (1sec) Defines the maximum period, in

fiftieths of second, allowed be-

tween receipt of the last charac-

ter of the three escape charac-

ter sequence from the DTE (es-

cape code guard time).

S18

decimal 0–255

0

Sets the length of time, in sec-

onds, that the modem conducts

a test (commanded by &Tn)

before returning to the com-

mand mode. If this register value

is zero, the test will not automat-

ically terminate; the test must be

terminated from the command

mode by issuing and &T0 or H

command. When S18 is non-

Advertising