Intelligent Motion Systems MDriveAC User Manual

Page 24

Advertising
background image

1-18

MDriveAC Plus Microstepping Hardware - Revision R121707

Relevant to Firmware Version 3.0.02

Pin Assignment and Description

P1 19-Pin M23 Connector - I/O and SPI Communications

Pin Assignment - P1 I/O and SPI

Connections

Pin #

Function

Description

Pin 1

Opto Reference

The signal applied to the Optocoupler Reference will

determine the sinking/ or sourcing configuration of the inputs.

To set the inputs for sinking operation, a +5 to +24 VDC

supply is connected. If sourcing, the Reference is connected

to Ground.

Pin 2

Enable

Enable/Disable Input will enable or disable the driver output

to the motor. In the disconnected state the driver outputs are

enabled in either sinking or sourcing configuration.

Pin 3

N/C

No Connect.

Pin 4

N/C

No Connect.

Pin 5

N/C

No Connect.

Pin 6

N/C

No Connect.

Pin 7

N/C

No Connect.

Pin 8

MOSI

Master-Out/Slave-In. Carries output data from the SPI Master

Pin 9

CS

SPI Chip Select. This signal is used to turn communications

on multiple MDM units on or off.

Pin 10

+5 VDC Output

Supply voltage for the MD-CC300-000 Cable ONLY!

Pin 11

GND

Communications Ground.

Pin 12

N/C

No Connect.

Pin 13

Direction/Channel B/

Clock Down

Direction input. The axis direction will be with respect to the

state of the Direction Override Parameter. It may also receive

quadrature and clock up type inputs if so configured.

Pin 14

N/C

No Connect.

Pin 15

N/C

No Connect.

Pin 16

SPI Clock

The Clock is driven by the SPI Master. The clock cycles once

for each data bit.

Pin 17

MISO

Master-In/Slave-Out. Carries output data from the MDM back

to the SPI Master.

Pin 18

Step Clock/Channel A/

Clock Up

Step Clock input. The step clock input will receive the clock

pulses which will step the motor 1 step for each pulse. It

may also receive quadrature and clock up type inputs if so

configured.

Pin 19

Fault Output

Open-Drain pending Over-temperature and Over-temperature

Fault. When device reaches the temperature specified by

the warning temperature the output will pulse at 1 second

intervals. When in Over-temperature fault the output will be

active continually.

Recommended

Cordset

MD-CS100-000 or

MD-CS101-000

Table 1.4.2: P1- 19-Pin M23 Pin Assignment and Description

NEED A

CABLE?

The following

cordset is

available to

interface to the 19-Pin M23

Connector:

Straight Termination

MD-CS100-000

Right Angle Termination

MD-CS-101-000

See Appendix E for details.