background image

2-8

MDriveAC Plus Microstepping Hardware - Revision R121707

Relevant to Firmware Version 3.0.02

Switch Interface Example

Switch Interface

(Sinking)

Switch Interface

(Sourcing)

+

+5 to +24VDC

Optocoupler Reference

Enable Input

SPST

Switch

GND

+

Enable Input

+5 to +24VDC

Optocoupler Reference

GND

SPST

Switch

Enable Input

MDriveACPlus

Microstepping

MDriveACPlus

Microstepping

Figure 2.1.6: Switch Interface Example

Fault (Temperature Warning) Output

The MDriveAC Plus Microstepping features an Open-Drain Fault output located at Pin 19 of connector P1. This
is an impending over-temperature and over-temperature fault.

When the internal temperature of the MDriveAC Plus reaches the temperature specified by the WARN_TEMP
parameter, the output will pulse at 1 second intervals (1/2 second on, 1/2 second off). When an over-temperature
fault state is reached the output will latch on.

The output will remain in the latched condition until a power cycle, or new parameter set from the IMS SPI Mo-
tor Interface.

Fault Output

Input Type

Open Drain

Drain-Source Voltage

+5 to +24 VDC

Drain Current

50 mA

Table 2.1.3: Fault Output Specifications

Advertising