Intelligent Motion Systems MDriveAC User Manual

Page 43

Advertising
background image

2-16

MDriveAC Plus Microstepping Hardware - Revision R121707

Relevant to Firmware Version 3.0.02

HCDT (Hold Current Delay Time)

The HCDT Motor Hold Current Delay sets time in milliseconds for the Run Current to switch to Hold Current when

motion is complete. When motion is complete, the MDriveAC Plus Microstepping will reduce the current in the windings

of the motor to the percentage specified by MHC when the specified time elapses.

MRC (Motor Run Current)

The MRC Motor Run Current parameter sets the motor run current to a percentage of the full output current of the

MDriveAC Plus driver section.

MHC (Motor Hold Current)

The MHC parameter sets the motor holding current as a percentage of the full output current of the driver. If the hold

current is set to 0, the output circuitry of the driver section will disable when the hold current setting becomes active. The

hold current setting becomes active HCDT setting mS following the last clock pulse.

DIR (Motor Direction)

The DIR Motor Direction parameter changes the motor direction relative to the direction input signal, adapting the direc-

tion of the MDriveAC Plus MicroDrive to operate as your system expects.

User ID

The User ID is a three character (viewable ASCII) identifier which can be assigned by the user. Default is IMS.

IMS SPI Motor Interface Button Functions

The following appear on all of the IMS SPI Motor Interface screens, but will only be documented here.

Factory

Clicking the Factory button will load the MDriveAC Plus Microstepping unit's factory default settings into the IMS

SPI Motor Interface.

Connected/Disconnected Indicator

Displays the connected/disconnected state of the software , and if connected, the port connected on.

Set

Set writes the new settings to the MDriveAC Plus . Un-set settings will display as blue text in the setting fields. Once

set they will be in black text. Setting the Parameters will also clear most Fault Conditions.

Exit

Disconnects and opens the Initialization dialog.

WARNING!

The Maximum

Allowable Setting is

67% Run Current

for 2.0 Amps RMS!