2-18

MDriveAC Plus Microstepping Hardware - Revision R121707

Relevant to Firmware Version 3.0.02

IMS Part Number/Serial Number Screen

The IMS Part Number and Serial Number screen is accessed by clicking "View > Part and Serial Numbers".

This screen is read-only and will display the part and serial number, as well as the fault code if existing. IMS may
require this information if calling the factory for support.

Fault Indication

All of the IMS SPI Motor Interface Screens have the Fault field visible. This read-only field will display a 2 charac-
ter error code to indicate the type of fault. The table below shows the error codes.

MDriveAC Plus Microstepping Fault Codes

Binary

Case*

Error

Code

Description

Action

To Clear

None

No Fault

4

CS

SPI Checksum Error

Error

Displayed

Write to MFM

(Set Button)

8

SC/CS

SPI Checksum Error/

Sector Changing

Error

Displayed

Write to MFM

(Set Button)

16

DFLT

Defaults Checksum

Error

Error

Displayed

Write to MFM

(Set Button)

32

DATA

Settings Checksum

Error

Error

Displayed

Write to MFM

(Set Button)

64

TW

Temperature Warning

Error

Displayed

Write to MFM

(Set Button)

*All Fault Codes are OR'ed together

Table 2.3.5: MDriveAC Plus Microstepping Fault Codes

IMS Part #

IMS Serial Number

Figure 2.3.9: SPI Motor Interface Part and Serial Number Screen