POST Error Messages

POST Message

Description

0132

Floppy drive B:

The system is not able to start the diskette in the drive. The
diskette might be damaged, incorrectly formatted, or inserted
incorrectly.

Action: Try another startable diskette. If the problem recurs,

have the system serviced.

If the problem recurs, have the system serviced.

0135

The floppy disk controller failed.

Action: Turn off the system and wait 30 seconds, then, turn it

back on. If the problem recurs, have the system
serviced.

0140

The shadow of the server BIOS failed.

Action: Turn off the system and wait 30 seconds; then, turn it

back on. If the problem recurs, have the system
serviced.

0175

The CPU modules are not compatible.

Action: Have the system serviced.

0176

The CPU failed. See Slot 1, CPU #1.

Action: Have the system serviced.

0177

The CPU failed. See Slot 1, CPU #2.

Action: Have the system serviced.

0178

The CPU failed. See Slot 2, CPU #1.

Action: Have the system serviced.

0179

The CPU failed. See Slot 2, CPU #2.

Action: Have the system serviced.

0180

The server is attempting to start with a failed CPU.

Action: Run the test programs to determine the cause of the

problem and the action to take. If the problem recurs,
have the system serviced.

0191

The CMOS battery has failed.

Action: Replace the real-time clock (see “Replacing the

Real-Time Clock” on page 137).