4 led description – Intel GD82559ER User Manual

Page 51

Advertising
background image

Datasheet

45

Networking Silicon — GD82559ER

will perform Auto-Negotiation or Parallel Detection with no data packets being transmitted.
Connection is then established either by FLP exchange or Parallel Detection. The PHY unit will
look for both FLPs and link integrity pulses. The following diagram illustrates this process.

6.4

LED Description

The PHY unit supports three LED pins to indicate link status, network activity and network speed.
Each pin can source 10 mA.

Link: This LED is off until a valid link has been detected. After a valid link has been detected,
the LED will remain on (active-low).

Activity: This LED blinks on and off when activity is detected on the wire.

Speed: This LED will be on if a 100BASE-TX link is detected and off if a 10BASE-T link is
detected. If the link fails while in Auto-Negotiation, this LED will keep the last valid link
state. If 100BASE-TX link is forced this LED will be on, regardless of the link status. This
LED will be of if the 10BASE-T link is forced, regardless of the link status.

MDI register 27 in

Section 9.3.12, “Register 27: PHY Unit Special Control Bit Definitions” on

page 71

details the information for LED function mapping and support enhancements.

Figure 16 on page 46

provides possible schematic diagrams for configurations using two and three

LEDs.

Figure 15. Auto-Negotiation and Parallel Detect

Force_Fail

Ability detect either by

parallel detect or auto-

negotiation.

10Base-T or

100Base-TX Link

Ready

FLP capable

LINK PASS

Parallel Detection

Auto-Negotiation

Look at Link Pulse;

Auto-Negotiation capable = 0

Auto-Negotiation capable = 1

Ability Match

Auto-Negotiation Complete bit set

Advertising