GD82559ER — Networking Silicon

78

Datasheet

10.4.2

Timing Parameters

10.4.2.1

Measurement and Test Conditions

Figure 27

,

Figure 28

, and

Table 24

define the conditions under which timing measurements are

done. The component test guarantees that all timings are met with minimum clock slew rate
(slowest edge) and voltage swing. The design must guarantee that minimum timings are also met
with maximum clock slew rate (fastest edge) and voltage swing. In addition, the design must
guarantee proper input operation for input voltage swings and slew rates that exceed the specified
test conditions.

Figure 27. Output Timing Measurement Conditions

Figure 28. Input Timing Measurement Conditions

Table 24. Measure and Test Condition Parameters

Symbol

PCI Level

Units

Notes

V

th

0.6V

CC

V

V

tl

0.2V

CC

V

V

test

0.4V

CC

V

T_off

T_on

T_val

V_step

V_test

V_test

V_test

V_th

V_tl

C L K

O U T P U T

D E L A Y

Tri-State

O U T P U T

C L K

I N P U T

V_test

V_test

V_test

V_th

V_tl

V_th

V_tl

T_h

T_su

inputs

valid

V_max