RECEIVE AND TRANSMIT

D RF gain and squelch

D Simple band scope

The IC-706MKIIG uses the same control, [RF/SQL],
to adjust one of either the RF gain or the squelch.
[RF/SQL] adjusts either the RF gain or the squelch
depending on the operating mode selected and the
condition of the RF gain item in initial set mode (p.
51; also see the table at right).

The

RF (Radio Frequency) gain

is used to adjust the

receiver gain.

• This control should be set to the 11 o’clock position for

normal use.

• Shallow rotation moves the S-meter to the right indicating

the signal strength which can be received.

The

SQUELCH

removes noise output from the

speaker (closed condition) when no signal is
received. The squelch is particularly effective for FM.
It is also available for the other modes.

• When operating in FM, first rotate the control fully coun-

terclockwise. Then, rotate the control clockwise to the
point where the noise just disappears. This is the best
position. The squelch does not open for weak signals
when it is set too deep.

• A segment appears in the S-meter to indicate the S-meter

squelch level.

• [RF/SQL] control priority

AF

RF/SQL

Max. RF gain position

RF gain
decreases

Same effect as at
the center position

AF

RF/SQL

Deep

Squelch
opens

S-meter squelch

threshold point

Noise squelch

threshold point

This function allows you to visually “sweep” an area
surrounding the set frequency for other signals.
Detected signals are indicated graphically in the dot
matrix section of the display.

Set a mode and frequency.

Select G1.

• Push [DISPLAY] 1 or 2 times if M or S appears.
• Push [MENU] one or more times to select G1.

Push [F-1] one or more times to select the desired
steps.

• Each dot corresponds to a step for the indicated fre-

quency.

• 0.5, 1, 2, 5, 10, 20 and 100 kHz can be set for the scope

step.

Push [F-3] to start the sweep.

• “___” (below SWP) flashes while sweeping.
• The receive audio is muted while sweeping.

Rotate the main dial if you want to monitor the dis-
played signals.

• The sweep marker indicates the location of the dis-

played frequency in the sweep readout.

• If the displayed frequency is outside of the sweep read-

out (determined by the sweep width), the sweep mark-
er flashes.

Push [F-2] to return the frequency to the start of a
sweep.

• The sweep marker moves back to the center position.

1k

SWP

2k

SWP

2k

SWP

2k

SWP

___

2k

SWP

Select sweep width
([F-1])

Start sweep
([F-3])

Sweep is finished
([F-3] again)

Move sweep marker
(main dial)

2k

SWP

Returns to previous
frequency ([F-2])

sweep marker

Note: The recommended
position for RF gain is the
11 o’clock position since
this sets RF gain to the
max.
When set to AUTO, SQL is
active in FM/WFM/AM; RF
is active in SSB/CW/RTTY.

Note: Use the attenuator or turn OFF the preamp when
using the band scope on a band containing a lot of noise.

Initial set mode
setting

USB, LSB,
CW, RTTY

AM, FM, WFM

SQL*

1

SQL

SQL

AUTO

RF GAIN

SQL

RF • SQL*

2

RF/SQL

RF/SQL

*

1

Default; *

2

Default for USA version.