60

10

OPTIONAL INSTALLATIONS/SETTINGS

CR-282

HIGH

-

STABILITY CRYSTAL UNIT

By installing the CR-282, the total frequency stability
of the transceiver will be improved.

Remove the bottom cover as shown on the oppo-
site page.

Remove the 5 screws and 2 flat cables holding the
PLL unit in place.

Remove the existing crystal unit.

Put the CR-282 in the space available as shown in
the diagram.

Adjust the reference frequency at L601 using a fre-
quency counter (60.00000 MHz).

Return the shield case and bottom cover to their
original positions.

CR-282 frequency stability: ±0.5 ppm

(–30°C to +60°C;

–22°F to +140°F)

IF filters

Several IF filters are available for the IC-706MKIIG.
Choose a filter most appropriate to your operating
needs.

Note: After filter installation, specify the installed filter
using initial set mode (items 9, 10). Otherwise, the
installed filter will not function properly.

FL-100

CW NARROW FILTER

500 Hz/–6 dB

FL-101

CW NARROW FILTER

250 Hz/–6 dB

FL-103

SSB WIDE FILTER

2.8 kHz/–6 dB

FL-223

SSB NARROW FILTER

1.9 kHz/–6 dB

FL-232

CW/RTTY NARROW FILTER

350 Hz/–6 dB

Remove the top cover as shown on the previous
page.

Install the desired filter as shown in the diagram
below.

• These filters can be installed in either direction.

Replace the top cover.

Filter

PLL unit

CR-282

Reference freq. check point

(60.00000 MHz)

ribbon
cable

ribbon
cable

existing
crystal

L601

PLL unit (bottom)

Advertising