Priority watch, S2 scn sel v/m, S2 scn pri v/m – Icom I706MKTMG User Manual

Page 47: Select vfo mode, then set a frequency, Close the squelch with [sql, Select s2, then push, Pri] to start the watch, Scn] to start the mem- ory scan, Push, Scn] to start the scan

Advertising
background image

44

5

MEMORY AND SCAN OPERATION

Select VFO mode, then set a frequency.

Close the squelch with [SQL].

Set the desired memory channel as the watching
channel.

Select S2, then push [

(F-2)

PRI] to start the watch.

• Decimal point blinks while scanning.

When the scan detects a signal, the scan pauses
for 10 sec. or until the signal disappears, depend-
ing on the resume setting.

To cancel the scan push [

(F-2)

PRI].

Note: The paused condition when detecting a signal
differs depending on the scan resume condition.
resume on: pauses for 10 sec.
resume off: pauses until the signal disappears.

Select memory mode.

Close the squelch with [SQL].

Select S2, then push [

(F-1)

SCN] to start the mem-

ory scan.

• Decimal point blinks while scanning.

Push [

(F-2)

SEL] to change the memory scan to

select memory scan.

• Push [

(F-2)

SEL] for 2 sec. to clear all select memory

channels.

When the scan detects a signal, the scan stops or
pauses depending on the resume setting.

To cancel the scan push [

(F-1)

SCN].

Note: Two or more memory channels must be desig-
nated as select memory channels for select memory
scan to start.

S2 SCN SEL V/M

Select
memory mode

Designate
“S.”

F-1

F-2

Push [

(F-1)

SCN], then [

(F-2)

SEL].

CH

S

MEMO

P

O

S1

5

5

3

7

9

20

40

10

60dB

USB

Select memory mode.

Close the squelch with [SQL].

Select S2, then push [

(F-1)

SCN] to start the scan.

• Decimal point blinks while scanning.

When the scan detects a signal, the scan stops or
pauses depending on the resume setting.

To cancel the scan push [

(F-1)

SCN].

Note: Two or more memory channels must be pro-
grammed for memory scan to start.

S2 SCN SEL V/M

Select
memory mode

F-1

then push [

(F-1)

SCN]

CH

MEMO

P

O

S1

5

5

3

7

9

20

40

10

60dB

USB

Select VFO mode.

Select the desired operating mode.

• The operating mode can also be changed while scan-

ning.

Set [SQL] open or closed.

• See page a left for squelch condition.

Select S2, then push [

(F-1)

SCN] to start the scan.

• Decimal point blinks while scanning.

When the scan detects a signal, the scan turns
OFF, pauses or ignores it depending on the
resume setting and the squelch condition.

• During scan [TS] can be used only when resume is ON.

To cancel the scan push [

(F-1)

SCN].

Note: If the same frequencies are programmed into
the scan edge memory channels 1A and 1B, pro-
grammed scan does not start.

Programmed scan operation

Memory scan operation

Select memory scan operation

S2 SCN PRI V/M

Select
VFO mode

Select watching
channel

F-2

Push [

(F-2)

PRI].

CH

P

O

S1

5

5

3

7

9

20

40

10

60dB

USB

VFO A

Priority watch

CH

VFO A

P

O

S1

5

5

3

7

9

20

40

10

60dB

USB

S2 SCN PRI V/M

Select
VFO mode

F-1

then push [

(F-1)

SCN]

Advertising
This manual is related to the following products: